Both European 11mm pole distance and American 8mm pole distance available.
1 Part number:4120
2 Contact arrangement:A:1A;B:1B;C:1C
3 Enclosure S: Wash tight;Z: Flux proof;
O: Unenclosed
4 Contact current:30:30A;40:40A;45:45A
5 Coil rated voltage(V):DC:6,9,12,18,24
6 Coil power:1.6:1.6W;1.9:1.9W
7 Terminal distance type:U:USA;E:European
CAUTION:
1.For the intermediate current, it only applies to the room temperature.
2.For the open type relays, the min. Switching current and min. Switching voltage is 100mA/6VDC.
CAUTION:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Insulation Resistance |
100MΩ min (at 500VDC) |
Item 4.11 of IEC 61810-7 |
Dielectric Strength Between Contacts Between Contact and Coil |
50Hz 500V 50Hz 750V |
Item 4.9 of IEC 61810-7 Item 4.9 of IEC 61810-7 |
Shock Resistance |
196m/s² 11ms |
Item 4.26 of IEC 61810-7 |
Vibration Resistance |
10Hz-40Hz Double amplitude 1.27mm |
Item 4.28 of IEC 61810-7 |
Terminals Strength |
10N |
Item 4.24 of IEC 61810-7 |
Ambient Temperature |
-40℃~125℃ |
|
Relative Humidity |
5% to 85% |
Item 4.16 of IEC 61810-7 |
Mass |
19g (Unenclosed) 21g |
Item 4.7 of IEC 61810-7 |