Suitable for automatic control, telecommunication equipment, household electrical appliances and machinery electrical facilities.
1 Part number:JQX-13F
2 Contact arrangement:2A:2A; 2B:2B; 1C:1C; 2C:2C
3 Terminal:a:inserting type;b:PCB type
4 Coil rated voltage(V):AC:6,12,24,36,48,110,120,220,240
DC:6,12,24,36,48,110
5 Cover:1:1Mode; 2:2 Mode
6 Coil transient suppression:
L:with LED
D:with diode
LD:with LED & diode
NIL:standard
CAUTION:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
CAUTION:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Insulation Resistance1' |
1000MΩ min (at 500VDC) |
Item 4.11 of IEC 61810-7 |
Dielectric Strength11 Between Contacts Between Contact and Coil |
50Hz 1000V 50Hz 1500V |
Item 4.9 of IEC 61810-7 Item 4.9 of IEC 61810-7 |
Shock Resistance |
98m/s² 11ms |
Item 4.26 of IEC 61810-7 |
Vibration Resistance |
10Hz~55Hz Double amplitude 1.5mm |
Item 4.28 of IEC 61810-7 |
Terminals Strength |
8N 4N(PC type) |
Item 4.24 of IEC 61810-7 |
Ambient Temperature |
-40℃~70℃ |
|
Relative Humidity |
5% to 85% |
Item 4.16 of IEC 61810-7 |
Mass |
37g |
Item 4.7 of IEC 61810-7 |
Note: 1). When testing, coil terminals should be connected , if LED is installed in relay .