Latching relay.
100A contact switching capability.
Max.Inrush current of 500A/2ms.
DC load capability of 100A/60VDC.
Electrical endurance capability: breaking under 2000A for 0.3ms for 300 times.
Suitable for smart home, PV, automatic equipment, smart meter, etc.
1 Part number: NT96L
2 Contact arrangement: A:1A;C:1C;
3 Coil: Nil:Single coil; D:Double coils
4 Enclosure: Z: Flux proof; S: Wash tight
5 Polarity: Nil: Standard; R: Reverse polarity
6 Type of load: Nil: AC rating; L:DC rating
7 Contact gap: Nil: Standard; S:1.5mm
8 Coil rated voltage(V): DC: 6,9,12,24,48
1) 1.5mm contact gap only applies to A type.
CAUTION:
1.When latching relays are installed in equipment, the latch and reset coil should not be powered simultaneously. Coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three times the specified operate time of the
relay. If these conditions are not followed, it is possible for the relay to in be the magnetically neutral position .
2.The above set voltage, reset voltage are the test value for relay without load. Please use 1~1.5 times of rated voltage to drlve the relay for your application
Insulation Resistance | 1000MΩ min (at 500VDC) | Item 4.11 of IEC 61810-7 |
Dielectric Strength Between Contacts Between Contact and Coil |
50Hz
1500V 50Hz 4000V |
Item
4.9 of IEC 61810-7 Item 4.9 of IEC 61810-7 |
Creepage Distance | 8mm | |
Shock Resistance | Functional: 98m/s2 11ms | Item 4.26 of IEC 61810-7 |
Destructive:980m/s2 11ms | ||
Vibration Resistance | 10Hz~55Hz Double amplitude 1.5mm | Item 4.28 of IEC 61810-7 |
Ambient Temperature | -40℃~70℃ | |
Relative Humidity | 5% to 85% | Item 4.16 of IEC 61810-7 |
Mass | 40g | Item 4.7 of IEC 61810-7 |
CAUTION:
In case of no tolerance shown in outline dimension: outline dimension ≤1mm,tolerance should be±0.2mm;outline dimension >1mm and ≤5mm, tolerance should be±0.3mm; outline dimension >5mm, tolerance shouldbe±0.4mm.