Single and double coils magnet latching relay available.
Switching capacity up to 50A.
PC board mounting.
1 Part number:NT95L
2 Contact arrangement:A:1A
3 Coil:Nil:Single coil; D:double coils
4 Enclosure:Z: Flux proof
5 Polarity:Nil: standard; R: reverse polarity
6 Coil rated voltage(V):DC:6,9,12,24,48
CAUTION: 1.For the intermediate current(10mA/6VDC~100mA/28VDC), it only applies to the room temperature.
CAUTION:
1.When latching relays are installed in equipment, the latch and reset coil should not simultaneously. Coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three times the specified operate time of the relay. If these conditions are not followed, it is possible for the relay to in be the magnetically neutral position .
2.Switching voltage is for test purpose only and are no to be used as design criteria.
Insulation Resistance |
1000MΩ min (at 500VDC) |
Item 4.11 of IEC 61810-7 |
Dielectric Strength Between Contacts Between Contact and Coil |
50Hz 1500V 50Hz 4000V |
Item 4.9 of IEC 61810-7 Item 4.9 of IEC 61810-7 |
Creepage Distance |
8mm |
|
Shock Resistance |
Functional: 98m/s² 11ms Destructive: 980m/s² 11ms |
Item 4.26 of IEC 61810-7 |
Vibration Resistance |
10Hz~55Hz Double amplitude 1.5mm |
Item 4.28 of IEC 61810-7 |
Terminals Strength |
10N |
Item 4.24 of IEC 61810-7 |
Ambient Temperature |
-40℃~70℃ |
|
Relative Humidity |
5% to 85% |
Item 4.16 of IEC 61810-7 |
Mass |
25g |
Item 4.7 of IEC 61810-7 |