Product in accordance to IEC60335-1 available.
1 Part number:NT75H
2 Contact arrangement:A:1A; C:1C
3 Enclosure:S: Wash tight; Z: Flux proof
4 Coil power:0.25:0.25W; 0.41:0.41W
5 Pin distance:5:5mm
6 Contact current:25:25A; NIL:20A,16A
7 Contact plating:Nil:Standard; G:Au plated
8 W: 335 compliant Nil:Standard
9 Coil rated voltage(V):DC: 5,6,9,12,18,24,48
CAUTION:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Insulation Resistance |
1000MΩ min (at 500VDC) |
Item 4.11 of IEC 61810-7 |
Dielectric Strength Between Open Contacts Between Contact and Coil |
50Hz 1000V 50Hz 5000V |
Item 4.9 of IEC61810-7 Item 4.9 of IEC 61810-7 |
Surge Voltage (Between Coil and Contact) |
10kV (1.2/50 us) |
Item 4.10 of IEC 61810-7 |
Shock Resistance |
Functional:98m/s² 11ms |
Item 4.26 of IEC 61810-7 |
Destructive:980m/s² 11ms |
||
Vibration Resistance |
10Hz-55Hz Double amplitude 1.5mm |
Item 4.28of IEC 61810-7 |
Terminals Strength |
10N |
Item 4.24 of IEC 61810-7 |
Ambient Temperature |
-40℃~105℃ |
|
Relative Humidity |
5% to 85% |
Item 4.16 of IEC 61810-7 |
Mass |
14g |
Item 4.7 of IEC 61810-7 |