telecommunication facilities and remote control facilities.
1 Part number:NG6D
2 Contact arrangement:A:1A
3 Coil rated voltage (V):DC:5,12,24
4 Contact plating option: G:Au plated
CAUTION:
Relays previously tested or used above 10mA resistive at 6VDC maximum or peak AC open circuit are not recommended for subsequent use in low level applications.
CAUTION:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Insulation Resistance |
1000MΩ min (at 500VDC) |
Item 4.11 of IEC 61810-7 |
Dielectric Strength Between Contacts Between Contact and Coil |
50Hz 750V 50Hz 3000V surge voltage:6kV |
Item 4.9 of IEC 61810-7 Item 4.9 of IEC 61810-7 |
Shock Resistance |
Functional:98m/s² 11ms Destructive:980m/s² 6ms |
Item 4.26 of IEC 61810-7 |
Vibration Resistance |
10Hz-50Hz Functional & Destructive: Double amplitude 1.5mm |
Item 4.28 of IEC 61810-7 |
Terminals Strength |
5N |
Item 4.24 of IEC 61810-7 |
Ambient Temperature |
-25℃~70℃ |
|
Relative Humidity |
5% to 85% |
Item 4.16 of IEC 61810-7 |
Mass |
3g |
Item 4.7 of IEC 61810-7 |