Creepage distance >8mm.
1 Part number:N68F
2 Contact arrangement:A:1A;C:1C
3 Enclosure:S:Wash tight;
Z:Flux proof
4 Contact current:8A
5 Coil rated voltage(V):DC:5,6,12,18,24,48
6 Resist heat class:B:130; F:155
CAUTION:
1.For the intermediate current, it only applies to the room temperature.
2.For gold plated version, the min. Switching current and min. switching voltage is 50mA/6VDC; for non gold plated version(standard type),the min. switching current and min. switching voltage is 100mA/6VDC.
CAUTION:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
3.Unless otherwise stated, the rated coil voltage specified in coil parameter table shall be used for all tests and its application to the relay.
Insulation Resistance |
1000MΩ min (at 500VDC) |
Item 4.11 of IEC 61810-7 |
Dielectric Strength Between Contacts Between Contact and Coil |
50Hz 1000V 50Hz 5000V |
Item 4.9 of IEC 61810-7 Item 4.9 of IEC 61810-7 |
Shock Resistance |
Functional: 98m/s² 11ms Destructive: 980m/s² 6ms |
Item 4.26 of IEC 61810-7 |
Vibration Resistance |
10Hz-500Hz Double amplitude 1.5mm 200m/s² |
Item 4.28 of IEC 61810-7 |
Terminals Strength |
10N |
Item 4.24 of IEC 61810-7 |
Ambient Temperature |
-40℃~85℃ |
|
Relative Humidity |
5% to 85% |
Item 4.16 of IEC 61810-7 |
Mass |
8.2g |
Item 4.7 of IEC 61810-7 |